Machine not working
Everything is placed switched off, the double click on power, redstone, every machine and generator status, heat and heat sinks.
The mod's machines say in their screen why they stand. Here is what each status means and what to do. You can see the status without the screen too: look at the machine with WAILA.
Check first
- The energy tier. A machine takes energy of its own tier and lower. A higher line needs a transformer, or it blows up (a server can turn explosions off: then the machine smokes and takes no energy). A cable above its tier burns out.
- The cable reaches the machine. Energy goes along the cable from the generator; a storage gives it out of its output side.
- The redstone mode. The button in the screen: always / with a signal / without a signal.
How the network works — energy network guide, first steps — first energy.
Statuses
Machines
| Status in the screen | What to do |
|---|---|
| Switched off | The machine is off — that's how it's placed. Open its screen and press the power button (top right). If it asks for a double click, the line is above the machine's input: put in a transformer, or it blows up. |
| No power | Not enough energy for an operation: check the generator, the cable (has it burnt out?) and that the line's tier isn't below the machine's. The machine's buffer shows in its screen. |
| Idle | Nothing to do: no input, or this machine has no recipe for it (check in NEI or the wiki). |
| Output full | The output slot is full: take the product out — with a pipe, a hopper or by hand. |
| An output tank holds another fluid | The output tank holds another fluid: empty it with the × above the tank. |
| Redstone hold | Held by its redstone mode. The mode button in the screen: always works, works with a signal, or works without a signal. |
| Overheated blast furnace, Czochralski, stepper, ion implanter | Heat reached 100: the machine stands until it cools to 70 and carries on by itself. No blast, but an operation that hit the pause gives double the defects. Add heat sinks: with 2 the heat stays flat. |
| Keeping warm induction furnace | Keeps itself warm with nothing to smelt (a little energy) so the next smelt runs fast at once. That's normal. |
Generators and reactors
| Status in the screen | What to do |
|---|---|
| Switched off | The generator is off — that's how it's placed. Switch it on with the power button in its screen. |
| Redstone hold | Held by its redstone mode — change the mode in its screen or remove/give the signal. |
| Buffer full | The buffer is full — nobody takes the energy. Cable it to machines or storage. Reactors throttle down and heat up with a full buffer. |
| Idle | Waiting: nothing to work with (see the status line and the hint in its screen). |
| No fuel solid fuel, combustion, turbines | No fuel: coal or wood into the solid fuel one; liquid fuel or gas into the tank. What burns and how much — generators. |
| No sunlight solar panels | Night, rain, or the panel can't see the sky — no blocks above it. |
| No rotor wind turbine | Put a rotor into the generator's slot. |
| No wind wind turbine | Too low or too cramped: full power at height 96, each block round the rotor takes 4%. |
| No current water wheel | It needs flowing water at its sides — still source blocks don't turn it. |
| No temperature difference thermoelectric | It needs a hot-and-cold pair: lava on one side, water on another. |
| No capsules RTG | Put in radioisotope capsules. It radiates — see radiation. |
| Water tank full fuel cell | The water tank (the reaction makes water) is full — pump it out with a pipe. |
| Igniting reactors | Igniting: the reactor builds its start charge. Wait; it needs fuel and coolant. |
| No deuterium fuel reactors | No deuterium fuel — feed it into the tank. Making deuterium — gas calculator. |
| No Li-Blanket Module fusion reactor | Put in a Li-Blanket Module, it doesn't light without one. |
| Blanket module depleted fusion reactor | The blanket module is spent: replace it and light the reactor again. |
| No coolant! reactors | No coolant (helium): the reactor burns and heats up until it stops. Feed it coolant. |
| Overheated: reactor shut down reactors | Overheated and shut down (no blast). Let it cool, free the buffer or remove extra Overdrive upgrades — then light it again. |
| No ring of 8 coils Tokamak, Tokamak XV | The structure isn't built: the Tokamak needs a ring of 8 coils. Layouts — multiblocks. |
| Plasma put out Tokamak XV | The plasma was put out safely (by the button or argon before a breakdown). Light it again with the button in its screen. |
| Plasma breakdown Tokamak XV | A plasma breakdown: a burst of radiation, coils knocked out. Rebuild the structure; keep argon for a soft stop. |
Heat
The blast furnace, Czochralski (and EV), stepper (and EV) and ion implanter heat up: +1 per working tick. At 100 the machine pauses, cools to 70 and carries on by itself — it doesn't explode. Without heat sinks that's 100 ticks of work, then a cycle of 30 ticks of work and 15 of pause. An operation that hit the pause gives double the defects.
| Heat sinks | What happens |
|---|---|
| 0 | a pause after 100 ticks, then it stands a third of the time |
| 1 | a pause after ~300 ticks, then 90 ticks of work and 15 of pause |
| 2 | the heat stays flat — it works without pauses |
| 3+ | it cools while working |
The heat sink is a machine upgrade. Defects and the Quality module — on the same page.
Pipes and fluids
Corrosive fluids are, for example, hydrochloric and hydrofluoric acids, fluorine and boron trichloride.
Carry them only in PTFE pipes: any other pipe breaks after about 10 seconds of contact and the fluid is lost.
Machines themselves are not harmed. Don't mix different fluids in one pipe.
PTFE pipe →